Lots of people charge for motorcycle service and workshop manuals online which is a bit cheeky I reckon as they are freely available all over the internet. £5 each online or download them in here for free!!
View and Download GE EnFlow IV operator's manual online. Fluid / Blood Warming System. EnFlow IV Medical Equipment pdf manual download. The system rapidly and download ge tuffsat user's manual contains hundreds of two. Enflow service Manual and gives directions on setting the hospital.
Select your manufacturer from the list below or click here for the full list including manufacturers not mentioned below and other misc manuals
Adly Service Manuals
AJS Service Manuals
Aprilia Service Manuals
Bajaj Service Manuals
Barossa Service Manuals
Baotian Service Manuals
Benelli Service Manuals
Beta Service Manuals
BMW Service Manuals
BSA Service Manuals
Buell Service Manuals
Cagiva Service Manuals
Classic Bike Service Manuals
CPI Service Manuals
Daelim Service Manuals
Derbi Service Manuals
Diamo Service Manuals
Ducati Service Manuals
GasGas Service Manuals
Gilera Service Manuals
Harley Service Manuals
Honda Service Manuals
Husqvarna Service Manuals
Jonway Service Manuals
Kawasaki Service Manuals
KTM Service Manuals
Malaguti Service Manuals
Piaggio Vespa Service Manuals
Suzuki Service Manuals
TNG Service Manuals
Triumph Service Manuals
Unites Motors Service Manuals
Yamaha Service Manuals
AJS Service Manuals
Aprilia Service Manuals
Bajaj Service Manuals
Barossa Service Manuals
Baotian Service Manuals
Benelli Service Manuals
Beta Service Manuals
BMW Service Manuals
BSA Service Manuals
Buell Service Manuals
Cagiva Service Manuals
Classic Bike Service Manuals
CPI Service Manuals
Daelim Service Manuals
Derbi Service Manuals
Diamo Service Manuals
Ducati Service Manuals
GasGas Service Manuals
Gilera Service Manuals
Harley Service Manuals
Honda Service Manuals
Husqvarna Service Manuals
Jonway Service Manuals
Kawasaki Service Manuals
KTM Service Manuals
Malaguti Service Manuals
Piaggio Vespa Service Manuals
Suzuki Service Manuals
TNG Service Manuals
Triumph Service Manuals
Unites Motors Service Manuals
Yamaha Service Manuals
Have something to add? Come and say hi onFacebook
One moment please...
Not A Member?Sign Up
- Documents
- Parts
- Videos
- News
DESCRIPTION
The right temperature, in the right place, at the right time.When it comes to fluid warming, there is a system that can help you maintain normothermia with accuracy, mobility and speed. The enFlow* system from GE Healthcare delivers the right temperature in the right place at the right time. enFlow can help providers deliver higher quality care to more people—part of GE’s healthymagination commitment.
enFlow can help maintain normothermia across your patient population with accuracy, mobility and speed.
The Right Temperature
By consistently helping to maintain the right patient temperature, enFlow brings the opportunity for both clinical and economic benefits to your hospital. Maintaining normothermia can help lessen complications and speed up recovery time – all while reducing length of stay and hospital costs.
The Right Place
True system mobility and a small transferable cartridge allow enFlow to help maintain normothermia in the right place-- throughout all care areas. It can be used before, during and after procedures, and because its cartridge is easily transported from room to room, enFlow maintains your workflow while saving steps.
The Right Time
The enFlow system enables warmed infusate delivery at the right time across all clinical areas—right away, and within seconds. Its low priming volume reduces the time needed to reach temperature set point thus allowing the warming process to start quickly, while its close proximity to the patient reduces heat loss across the IV line.
enFlow can help maintain normothermia across your patient population with accuracy, mobility and speed.
The Right Temperature
By consistently helping to maintain the right patient temperature, enFlow brings the opportunity for both clinical and economic benefits to your hospital. Maintaining normothermia can help lessen complications and speed up recovery time – all while reducing length of stay and hospital costs.
The Right Place
True system mobility and a small transferable cartridge allow enFlow to help maintain normothermia in the right place-- throughout all care areas. It can be used before, during and after procedures, and because its cartridge is easily transported from room to room, enFlow maintains your workflow while saving steps.
The Right Time
The enFlow system enables warmed infusate delivery at the right time across all clinical areas—right away, and within seconds. Its low priming volume reduces the time needed to reach temperature set point thus allowing the warming process to start quickly, while its close proximity to the patient reduces heat loss across the IV line.
FORUMSView All (1)
Ask a New Question1Reply2 years ago | 2 years agoManual Does anyone have the service manual for these that you can send me?DaveReply |
FEATURES
Accuracy
- The system warms fluids automatically to 40 ± 2°C and has redundant sensors to ensure fluid temperature accuracy.
- The lightweight warmer (9.5 oz) can be placed close to the patient – allowing less opportunity for fluid-cooling in the IV line.
- It has a low priming volume (4mL), which reduces waste and improves control over fluid composition.
- The warmer incorporates a layer that transfers heat effectively and prevents hot spotsMobility
- When it’s time to move, the cartridge and the IV set are removed from the warming unit only to be reinserted into a warmer in the next area.
- The warming unit and power source are highly durable and have been shock and vibration tested.
- The cartridge may stay in-line to protect the IV set from potential infection – whether fluid is being warmed or not.
- The enFlow cartridge can be used for 24 hours of continuous patient warming.Speed
- It warms fluids rapidly (18 s or less) to a temperature of 40 °C, so there’s no time spent waiting to warm (other warmers can take over 10 min).
- The cartridge attaches in-line to standard IV sets at the start of procedures, so there’s no additional set-up or tubing requirements.
- It offers one-button operation. It's intuitive and relatively easy to operate, simply turn on the power and be warming within seconds.
- It requires little preventive maintenance (five year schedule) and no calibrations.
SPECIFICATIONS
Height | 1.2 in |
Length | 5 in |
Weight | 9.7 oz |
Width | 2.5 yd |
Additional Specifications
Fluid Temperature Output: 40 °C ± 2 °C
Flow Rate Range: KVO to 200 mL/min
Flow Rate Range: KVO to 200 mL/min